Project Description

Water cooled chiller 13

Industrial Water Chiller Machine

Industrial water chillers are used in a variety of applications where chilled water or liquid are circulated through process equipment. Commonly used to cool products and machinery, water chillers are used in a multitude of different applications including injection molding, tool and die cutting, food and beverage, chemicals, lasers, machine tool, semi-conductors and more.

The function of an industrial chiller is to move heat from one location (usually process equipment or product) to another place (usually the air outside the manufacturing facility). It is very common to use water or a water/glycol solution to transfer the heat to and from the chiller which may require the process chiller to have a reservoir and pumping system. Regardless of your industry and process, making sure that you have sufficient cooling is critical to productivity and cost savings.

Contact Us Now

Product Description

Industrial Water Chiller is a machine that removes heat from a liquid via a vapor-compression, adsorption refrigeration, or absorption refrigeration cycles. This liquid can then be circulated through a heat exchanger to cool equipment, or another process stream (such as air or process water).
As a necessary by-product, refrigeration creates waste heat that must be exhausted to ambience, or for greater efficiency, recovered for heating purposes. Vapor compression chillers may use any of a number of different types of compressors. Most common today are the hermetic scroll, semi-hermetic screw, or centrifugal compressors. The condensing side of the chiller can be either air or water cooled. Even when liquid cooled, the chiller is often cooled by an induced or forced draft cooling tower.
Water cooled chiller 12
Water cooled chiller 11

Main Features of Industrial Water Chiller

  • Excellent cooling, quiet with low electric consumption;
  • Accurately maintains temperature range from 3℃ to 50℃;
  • Single,double or quadruple compressors combination available–economical and efficient.
  • Optional for RS485 communication function to realize automatic running.
  • Optional refrigerant:R407C,R410A,R314A,R404A.

Product Details

water-chiller-details-001water-chiller-details-004

Specific Parameters of Water Chiller

Model Unit XC-L12W XC-L15W XC-L20W XC-L25W XC-L30W XC-L40W XC-L50W
Cooling Capacity KW 39 51.7 71.9 81.4 108.5 144 160
Kcal/h 44505 45422 61902 70021 93361 123805 138621
Compressor Input Power KW 4.5×2 3.75×3 7.5×2 9×2 7.5×3 7.5×4 9.4×4
Rated Power HP 12 15 20 25 30 40 50
Power  3PH-380V/50HZ(200V/220V/415V 50HZ/60HZ)
Evaporator Type Shell and tube
Pipe Diameter inch 2” 2.5” 2.5” 3” 3” 4” 4”
Refrigerant Type R22
Quantity KG 5 7.5 11 11 12 18 18
Condenser

(water chiller)

Type Shell and tube condenser
Pipe Diameter inch 1.5” 2” 2” 2.5” 2.5” 3” 3”
Cooling Water Flow m³/h 5.03 7.1 8.84 10.06 13.6 17.76 21.9
Condenser

(air chiller)

Type High efficiency copper tube sleeve aluminum fin type + low noise outer rotor fan
Fan Power KW 420×2 800×2 420×3 800×3 800×3 420×6 800×6
Water Tank Capacity Liter 80 100 150 210 210 380 400
Pump Power KW 1.5 2.2 2.2 4 4 5.5 7.5
HP 2 3 3 5 5 7.5 10
Distance m 15 16 16 16 16 16 18
Flow Rate L/min 360 360 360 700 700 700 800
Safety Protection Compressor overheat protection, overcurrent protection, high and low pressure protection, over temperature protection, flow protection, phase sequence/phase loss protection, exhaust overheat protection, antifreeze protection
Dimensions mm 1500*850*1508 1850*1000*1600 2150*1000*1780 2400*1150*1800 2600*1150*1930 2300*2000*1800 2800*2100*1960

Application of Industrial chiller

In industrial application, chilled water or other liquid from the chiller is pumped through process or laboratory equipment. Industrial chillers are used for controlled cooling of products, mechanisms and factory machinery in a wide range of industries. They are often used in the plastic industries, injection and blow molding, metal working cutting oils, welding equipment, die-casting and machine tooling, chemical processing, pharmaceutical formulation, food and beverage processing, paper and cement processing, vacuum systems, X-ray diffraction, power supplies and gas turbine power generation stations (see Turbine inlet air cooling#Vapour compression chiller), analytical equipment, semiconductors, compressed air and gas cooling. They are also used to cool high-heat specialized items such as MRI machines and lasers, and in hospitals, hotels and campuses.

Water-cooled-chiller-application

Factory display

Our Factory

water chiller factory

Packaging

Our Service

Pre-sale Service

  1. Provide 24-hour technical consulting reply;
  2. Provide professional quoted price;
  3. Provide detailed product performance specification;
  4. According to product’s using condition, technicians will offer rationalization proposals to assist clients to select proper product types;
  5. Provide other corollary equipment according to client requirements.

In-sale Service

  1. Begin to supervise from raw material, its qualified rate can reach to 100%;
  2. Whole manufacturing process are in strict accordance with promised procedure requirements, product qualified rate can reach to 100%;
  3. Provide product’s inspection record of key junctures to customers;
  4. Provide production schedule photos to customers at regular intervals;
  5. Package and transport products strictly accordance with export standard;
  6. Provide transportation schedule information to clients timely.

After-sale Service

  1. Provide targeted installation video;
  2. Under the premise of correct installation, normal maintenance and using, we guarantee one-year warranty period;
  3. When warranty period has expired, our sold products enjoys lifetime guarantee repair, we only charge cost price for changing product’s standard component and sealing component;
  4. During installation and adjustment period, our after-sale service staff will communicate with customers frequently to know product’s running state in time. Assist customers to install and adjust products until customers are satisfied;
  5. If product has malfunction during operation period, we’ll offer you satisfied answer in time. We’ll reply you within 1 hour and provide solution or send staff to spot within 24 hours after receiving maintenance notification.
  6. Lifelong free technical support. Conduct satisfaction survey and inquiry equipment running condition to clients by telephone or e-mail semiannually from the first day of equipment running, put on records of acquired information;
  7. Provide assistant service if product is damaged during transportation.

Get In Touch With Us